All wodCrypt (12) wodSSH (10) wodSFTP (23) wodSSHServer (1) wodSSHTunnel (11) wodSSHpackage wodSFTPdll wodSSH.NET (10) wodSFTP.NET (24) wodFtpDLX.NET (22) wodWebServer.NET (10) wodAppUpdate (13) wodHttpDLX (8) wodFtpDLX (22) wodTelnetDLX wodFTPServer (3) wodWebServer (10) wodVPN wodXMPP (13) | All ** [Visual Basic] ** [C#] ** [VB.NET] ** Asynchronous File Download
Set Protocol property to change the protocol in below code
VB code
Dim WithEvents wodFtpDLX As wodFtpDLXCom Private Sub Form_Load() Set wodFtpDLX = New wodFtpDLXCom ' Set connection parameters wodFtpDLX.HostName = "xx" wodFtpDLX.Login = "xx" wodFtpDLX.Password = "xx" wodFtpDLX.Protocol = FTP ' Initiate the connection wodFtpDLX.Connect End Sub ' Connected event is triggered when Connection is successful/or fails. If connection failed ' ErrorCode will be <> 0, and in that case, ErrorText will contain description of an error ' which occured. Private Sub wodFtpDLX_Connected(ByVal ErrorCode As Long, ByVal ErrorText As String) If ErrorCode = 0 Then wodFtpDLX.GetFile "C:\", "/home/remote_filename" End If End Sub ' When method finishes execution, Done event is triggered. This is where we will disconnect. Private Sub wodFtpDLX_Done(ByVal ErrorCode As Long, ByVal ErrorText As String) wodFtpDLX.Disconnect End Sub C# code
private WeOnlyDo.Client.FtpDLX wodFtpDLX; private void Form1_Load(object sender, EventArgs e) { wodFtpDLX = new WeOnlyDo.Client.FtpDLX(); // Declare events wodFtpDLX.ConnectedEvent +=new WeOnlyDo.Client.FtpDLX.ConnectedDelegate(wodFtpDLX_ConnectedEvent); wodFtpDLX.DoneEvent +=new WeOnlyDo.Client.FtpDLX.DoneDelegate(wodFtpDLX_DoneEvent); // Set connection parameters wodFtpDLX.Hostname = "xx"; wodFtpDLX.Login = "xx"; wodFtpDLX.Password = "xx"; wodFtpDLX.Protocol = WeOnlyDo.Client.Protocols.FTP; // Initiate the connection wodFtpDLX.Connect(); } // When method finishes execution, Done event is triggered. This is where we will disconnect. void wodFtpDLX_DoneEvent(object Sender, WeOnlyDo.Client.FtpDoneArgs Args) { wodFtpDLX.Disconnect(); } ' Connected event is triggered when Connection is successful/or fails. If connection failed ' Args parameter will contain exception of an error void wodFtpDLX_ConnectedEvent(object Sender, WeOnlyDo.Client.FtpConnectedArgs Args) { wodFtpDLX.GetFile("C:\\", "/home/remote_filename"); } VB.NET code
Dim WithEvents wodFtpDLX As WeOnlyDo.Client.FtpDLX Private Sub Form1_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load wodFtpDLX = New WeOnlyDo.Client.FtpDLX ' Set connection parameters wodFtpDLX.Hostname = "xx" wodFtpDLX.Login = "xx" wodFtpDLX.Password = "xx" wodFtpDLX.Protocol = WeOnlyDo.Client.Protocols.FTP ' Initiate the connection wodFtpDLX.Connect() End Sub // Connected event is triggered when Connection is successful/or fails. If connection failed // Args parameter will contain exception of an error Private Sub wodFtpDLX_ConnectedEvent(ByVal Sender As Object, ByVal Args As WeOnlyDo.Client.FtpConnectedArgs) Handles wodFtpDLX.ConnectedEvent wodFtpDLX.GetFile("C:\\", "/home/remote_filename") End Sub 'When method finishes execution, Done event is triggered. This is where we will disconnect. Private Sub wodFtpDLX_DoneEvent(ByVal Sender As Object, ByVal Args As WeOnlyDo.Client.FtpDoneArgs) Handles wodFtpDLX.DoneEvent wodFtpDLX.Disconnect() End Sub |